) The Ciena 6500 Packet optical platform 2-Slot , 7-Slot ,14 Slot and 32 Slot Box is widely used . Retrieve commissioning scripts summary for a heterogeneous project (6500, Waveserver and Waveserver5) Create the commissioning scripts to configure 6500 eMOTR cards; Enroll a Z-Series network element; View Z-Series inventory; Service provisioning after commissioning; Change a network element connection profile; Commission and. x. Under Security, select Configuration. 16 Sep 2015. 1G-111. 6. . The 6500 Family comes in multiple chassis form factors, from a compact 2RU, up to full rack sizes, with the ability to scale from 100 Gb/s to 500 Gb/s per. 1/mcp. Local authentication is always used as a fallback in the event that authentication through a remote. WLAi FOTR module . Path tab is usually the default selection. Refer to the section “SNC Status Diagnostics” found in ciena document 6500 Packet-Optical Platform Control Plane Application Guide Layer 1 (OTN), NTRN71AA. The Performance Metrics or Performance Monitoring (PM) microservice orchestrates the collection of metrics from resources. Step 3: Now from site manager , go to configuration tab ---> Equipment and facility provisioning and select the. x. The 6500 offers integrated OTN and packet switching, for the based packet and OTN switching solutions; the configuration. Following the MCP installation, additional configuration of MCP is required based on the network element type(s) to be enrolled and the size of the network being managed. S. Choosing a Ciena OME 6500-D2 will increase your network support on the Ciena OME 6500-D7/S8 configuration allowing you to bridge the ethernet, WDM and TDM rack configurations providing the capacity to meet web-scale demand, as well as Ciena's 6500 Optical Platform Converges package, optical transport For 6500 Photonics OTS link (Fibre) and OMS link (ROADMLine), there are a few rules governing the total capacity: A maximum C-band allocation is 191. Perform a NE backup before the upgrade. I have several 6500 interfaces to Juniper gear that will take a "flap" where the Ethernet feed to a QSFP28 optic RXs errors and stops in one direction for 3-4 seconds. Number of Views 590. MCP supports the following TAPI object types. L1 (SONET/SDH and OTN) control planes uses the following key terminology:. S onver f w requir ore. 3_Admin_Security)_Issue1. 15000 THz/1528. ) In this animation shelf vies and Specific fix Slot f. 6500. Z-Series: Node unresponsive in Planet Operate due to throttling errors and High CPU utilization. show software. 3801 XGS-PON Optical Network Unit. pre-made ones from Ciena#100GCFP is installed in a Ciena 6500 shelf details (103. 00. x_Guide): 323-4001-100 - For All Configuration related stuff and general user guide6500 PACKET-OPTICAL PLATFORM RELEASE 13. The 3922 features a cost-effective 24 Gb/s switching fabric capacity, supporting two 1/10GbE and two 100M/1GbE fiber ports, and two 10M/100M/1GbE copper ports. View and Download Ciena 3930 Series hardware installation and start-up manual online. Sample JSONLesson objectives o2cb 4 1 copyright 2010 2014 ciena. MCP5. A backup profile contains details of the backup process, backup transfer locations and number of backup files to be maintained for the NE. 0) Public_IPV6_v1 (6500 specific policy)Ciena 6500 with module Card 4X10G OTR 4xXFP/4xSFP+ Brocade switch is 16Gb DCX 8510-8 at FOS v7. MCP provides a list of configurable parameters that are used for allocating SIDs. configuration with ROADM 6500-S8 Packet-Optical with DC power Compact 600G Packet/OTN Switch . The 6500-D2 is a 2RU chassis composed of two service card-carrying slots. The problem. Offers. 3930 Series switch pdf manual download. 1: If they don't match then continue to step-8. With the help of our Ciena Switch device template, you can easily discover your devices and start managing their configurations. When you select the check box for a unit, the settings are displayed in the lower part of the page. com) I guess it is not the same procedure and there are differences between CPL and 6500 procedure. ISL port set to 8Gb to Ciena 6500 using standard Brocade shortwave SFP. Also for: 170-3930-900, 170-3930-910, 170-3930-930, 5160. To use characters supported by devices in your network that are not in line with the MCP default set (for LSPs and Packet services), contact Ciena for instructions to customize the properties that govern the permitted character set. Advantages of Ciena’s packet/OTN switched solutions include:The Flow Recorder supports both Netflow and sFlow (including sFlow v5) protocols. Step 3: In the Product. 0 mode is incompatible with MCP deployments, which uses both C and L band photonic services, since MCP internal model will have a common OTS layer, but separate C and L band OMS termination points and associated forwarding entities. Bulk view of various device settings like NTP, RADIUS, License etc. 6, Issue 2 - Free ebook download as PDF File (. 1AE-2018 payload encryption for hop-by-hop or end-to-end regardless of the number of intervening devices. • NTK703PA-F01: 6500-T24 Shelf mounted at 3-38U in a 23-in 44U EIA Rack (26x18x84in, Blue) on a cushioned pallet packaged for vertical shipping. 24/7 in-flight data protection with wire-speed encryption As part of Ciena’s multi-layer security approach that ensures the confidentiality, integrity, and availability of data in the network, the 6500 offers advanced integrated AES-256Course Description. To turn off paging =. Bias-Free Language. Tech Touch Video: Live Chat Demo. Ciena’s 6500 Reconfigurable Line System (RLS) empowers network operators to efficiently address the highest-capacity networking requirements in today’s metro, long-haul, and Data Center Interconnect (DCI) networks. For more details on the command line, please refer to "323-1851-193_(6500_R12. This port is opened when VNC displays 2 through 10 are enabled; however, access control within the xdm (1) configuration disallows any access from remote machines. start the remote site application, correct the IPsec configuration between sites, restore the physical or networking issue) Additional Details: Not Applicable. Respond quickly to increasing end-user demands with on-demand connectivity, and scale to terabit switching capacity for efficient switching of 400G+. Attachment Circuits attached to the EVIs. issue. If these files are ever misconfigured, or if you need to restore the default files, you can always delete the current file and restart Nagios. MCP: Policy management for updating license server on network elements. Create a copy of the logrotate. conf file. SLAT process overview Nodal SLAT procedures Photonic layer provisioning procedures Photonic layer site testing procedures Fixed-plan terminal node procedures Passive OTS network procedures Wavelength addition and deletion Appendix A:. - probable cause (0000). software upgrade is done. 6500 Packet-Optical Platform Photonic Layer Guide, Part 1 of 3. 1 onwards, both the user-labels will be set as the name of the fiber OTS. 71K. A configured VLAN interface can serve the same purposes as a physical interface, including serving as the selected administrative interface. Interop Issue Cisco 4500 - Ciena 6500. Ciena6500. This Security Policy describes how the Ciena 6500 Packet-Optical Platform 4x10G meets the security requirements of Federal Information Processing Standards (FIPS). The 6500 Family comes in multiple chassis form factors, from a compact 2RU, up to full rack sizes, with the ability to scale from 100 Gb/s to 500 Gb/s per. Supports 4 GbE NNI/UNI ports including 2 100/1000 Base-X SFP ports and 2 dual-mode ports: RJ-45 10/100/1000 Base-T and 100/1000 Base-X SFPs. Steps. The "Edit" dialog displays. Ciena’s 3922 Platform is purpose-built for smaller capacity 1/10 Gb/s service delivery in a variety of business environments. 13 answers 2. MCP presence of pre-5. The results of the simulated link failures appear in Failure. VPLS is the default value assigned to E-Line services if the BPO-IFD file is not altered. I have connected console port to an Open gear Terminal server. Overview; Required files; Required users; Prerequisites. 49K views Top Rated Answers All Answers Amit G1 (Customer) 5 years ago Please use this link and under product documentation - ALL PRODUCTS. Ciena OME 6130 planning guide and hardware description. Security Target Ciena 6500 Packet Optical Platform 6 | P a g e 1. Tailored to address enterprise business requirements at the edge, the 6500-D2 Packet-Optical Platform is a compact 2RU chassis that cost-effectively extends the flexibility and resiliency of the 6500 platform from the core to the access. Click Edit. Ciena’s 6500 Packet Transport System (PTS) addresses the growing need to maintain profitable delivery of TDM services while future-proofing investments to an all-packet network modernization. Create a copy of the logrotate. The question is if the 6500 Ciena DWDM listed has been tested with Cisco 9706 MDS SAN Director and firmware NX-OS 8. Standalone License Server: 6500 Network Element fails to get license from License Server; SAOS 8. Network Element should have ISIS (or any other IGP protocol) commissioned and SR Enabled. Use this procedure to manually trigger the immediate resynchronization of the data stored in MCP, and the data stored on participating nodes, for an IP link or a dynamic MPLS tunnel. Steps. Completing the configuration of the MCP email service; Disabling the configuration of the MCP email service; Disabling Storage of Rolling Alarm Mutations; Enable license server data distribution to network elements; Web-based Site Manager installation. 1 Overview The module is the Ciena 6500 Packet-Optical Platform 4x10G, which is a daughter/mezzanine card designed for use on the 4x10G Encryption OTR1 circuit pack of the 6500 series Packet-Optical Platform. OneControl : 8700 and 5170 nodes are constantly resyncing. Topology Fundamentals 1-. When it gets to the 6500, it comes in on port 31/1 which is on the same virtual-switch and VLAN as port 14/1. com) I guess it is not the same procedure and there are differences between CPL and 6500 procedure. 4(2e) at 4Gbps speed ports. 6500 - planning guide. In the example, a 6500 provides a three part value of alarm (for example, 0380000000-0000-0000): - instance number (0380000000). Hi @Brian W1 (Customer) You can find this information on e. x, the 3928 operates as an IP router supporting NETCONF/YANG to enable an open SDN environment with full visibility via telemetry and automated provisioning using open APIs. It provides highly dense ROADM and amplifier configurations so you can quickly react to unpredictable traffic requirements by scaling nodal connectivity. 1_ (6500_R13. Click Save. Going to Configuration>Nodal Connections and do not see 'photonic connection option. The boot sequence is different on the Catalyst 6500/6000 and Cisco 7600 that run Cisco IOS System Software than the Cisco 7200 Series Router because the hardware is different. 6500 Packet-Optical Platform. 43 and Transport Interface 4X10G OTR 4X XFP/4X SFP+ with Encryption, we need to know if these Ciena DWDM have compatibility to connect to SAN Cisco MDS 9706 Multilayer Director with. Procedure 1-1 Installing a 6500 14-slot shelf (all variants), access panel, cooling fan modules, and air plenum Use this procedure to install the 14-slot 6500 shelf into a 19-inch, 23-inch, or ETSI equipment rack. MCP Documentation. Ciena uses cookies to ensure that we give you the best experience when visiting our website, as well as to enhance the overall quality of our site. Remove the switch from the packaging materials. ), Ciena 4200 series, Ciena 6500 and Ciena 8700 series. Building Industry Consulting Services International. James Herberich (Ciena Employee). Operators can leverage both photonicCiena’s Manage, Control and Plan (MCP) is a multi-layer Software Defined Networking (SDN) and Network Management System (NMS) platform. A handful of 6500 OTN, packet, and hybrid packet/OTN interfaces support a wide range of protocols, allowing for rapid response to service requests and faster time to revenue, even. • NTK703PA-F01: 6500-T24 Shelf mounted at 3-38U in a 23-in 44U EIA Rack (26x18x84in, Blue) on a cushioned pallet packaged for vertical shipping. Access the Ciena Portal and follow the steps below: Step 1: On the left vertical bar, select Knowledge. this should bring up all of the cards that are provisioned on the node. Upvote Upvoted Remove Upvote. (6500) Generate commissioning scripts for a homogeneous project (RLS). Collection of L2 interfaces using. Includes Ciena’s MCP multi-layer provisioning support for end-to-end network management control and planning. Retrieve commissioning scripts summary for a heterogeneous project (6500, Waveserver and Waveserver5) Create the commissioning scripts to configure 6500 eMOTR cards; Enroll a Z-Series network element; View Z-Series inventory; Service provisioning after commissioning; Change a network element connection profile; Commission and. MCP Installation Guide. Support for RLS L-Band C-Band was added to MCP 5. If the active flag is "unknown" then that is the root of the issue. Operators can leverage both photonicUsing a text editor such as vi, open the patch-lineup-hostadd. Resolution/Answer. x states Ciena has passed responsibility for providing the. No service management (no DVT or Prov’g for SONET/SDH switching) 6500. 3928. Select the date range for which the logs will be exported. Step 2: At SNC originating node Edit the SNCG and change its Primary State from IS to OOS. The display updates every 30 seconds. Step 2: Select Documentation. ciena. MCP DocumentationMCP DocumentationThis guide will walk you through the features and function available to when you join our community. 1 . Steps. 50I have a 6500 fixed grid network with CMD44, 50 GHz WSS, MLA3. Network admin: full control of network elements and services. 5” front bay drive configuration. Advantages of Ciena’s packet/OTN switched solutions include:Steps. ), Ciena 4200 series, Ciena 6500 and Ciena 8700 series. School Anna University, Chennai; Course Title EN MISC; Uploaded By prakashpavi18. Configure the following settings. The other 50% are not available (ping is down). The Cisco has a portchannel configuration in LACP which end's up in a Virtual Switch configuration in the Ciena 6500. PFC reduces the reactive component in the source AC current allowing higher power. Retrieve commissioning scripts summary for a heterogeneous project (6500, Waveserver and Waveserver5) Create the commissioning scripts to configure 6500 eMOTR cards; Enroll a Z-Series network element; View Z-Series inventory; Service provisioning after commissioning; Change a network element connection profile; Commission and. Ciena’s Coherent ELS is a coherent-optimized Open Line System (OLS) designed to meet next-generation photonic requirements at the network edge. conf file, as required. Ciena 3916 Configuration. 16 Sep 2015. When the IS-IS entry appears in the configuration hierarchy, click the arrow to its left to display the configuration interface. Table 2. 15000 THz/1528. mcpc file to the required folder on your computer. 3. required port configuration setting for the Brocade to properly interact with the 6500. Broadband Inter-Carrier Interfaces; B-ISDN Inter-carrier Interface. Using the MCP UI, select System > Configuration. The command one would issue to download a config via an SSH or Telnet session like "show run from CISCO". The alarms may be different depending on the software version you're running on your 6500 network - you should download the appropriate manuals from the Ciena portal (the Alarm Clearing guide is divided into two PDFs). For each of those resources, note the ID and input. After examining Adv Enet Config guide for SAOS, I am confused regarding port. Step 1: If a new database backup is required to be generated, execute the following command in CLI: database-backup <filename>Using a Phillips screwdriver, secure the module in place using the captive hold down screw on the right of the module. Allow Admin—Select to have this interface act. Log in to Host 0 as bpadmin user and navigate to /opt/ciena/loads/7. You can alter the boot system parameters with the boot command. - documentation identifier (0000). Does 6500 PTS(NTK614AA/fabric and Ntk695aa/interface) support 2. 72. AIPA Install Procedures; Creating the bpadmin user;. MCP: Policy management for updating license server on network elements. 3903x Installation and Commissioning Learning course; 39xx/511 Service Delivery, Aggregation and Virtualization Switches Product Fundamentals (009-3313-006) - find this under Support > Documentation > 3903 Service Delivery Switch or use search and select the version for your versionCommunity (v2)—Enter the SNMP community for the router, if SNMP v2 is used. 5K. Architected for high-capacity applications, Ciena’s 6500-D14/S14 configurations converge comprehensive Ethernet, TDM, and WDM capabilities with unconstrained hybrid packet/OTN switching and an intelligent control plane to maximize the bandwidth eficiency and flexibility of the overall network. This is a cheat list of the most used operational and troubleshooting Ciena Commands used in SAOS OS cli. After examining Adv Enet Config guide for SAOS, I am confused regarding port VLAN, port PVID and. Select the shelf; Edit the. rdp; Driver Tier: 1; Vendor: Ciena. Step 7. Collection of L2 interfaces using yang. Building Industry Consulting Services International. Instances of the service - EVIs. • Ciena’s vSwitch is a Data Plane Development Kit (DPDK)-based switch that provides service function chaining as wellFigure 1. ONID. Memory: 8 GB 1333 MHz. PM stats can be enabled on flow-points & IP interfaces on the device. curl -X GET ". 6500 only supports GMT. Via the Live Support Chat button on Support page. Pre-requisite: Restoration DLT/DTLSET should have created at originating node under Configuration-->Routing Profiles Step 1: Identify the SNC & SNCG which are down due to active fiber cut in network. pdf eziwigting. Step 1: Remove the fuse for the power card. 2 009-3218-022-Standard Revision A. So it is recommended that you keep the admin user (local to MCP and having Application admin and sysadmin roles) credentials handy to recover from such a situation. Repair Spare parts Download > Schematics Download > Ciena - 6500 (User Manual) User Manual Ciena 6500 - This User Manual - also called owner's manual or operating. CHAPTER 38-1 Cisco IOS Software Configuration Guide, Release 15. A local or remote database backup can be performed using the command outlined in the RLS User Guide "Procedure 127", Backup and restore section. Under Security, select Configuration. Cienas 6500 supports both muxponder- and central fabric-. Table 1-1 Catalyst 6500 Series Switch Installation Process. With Ciena’s multi-layer. 5. 6 Tb/s. Architected for high-capacity applications, Ciena’s 6500-D14/S14 configurations converge comprehensive Ethernet, TDM, and WDM capabilities with unconstrained hybrid. 32500 THz/1566. 2 6500 RA logs can result in 6500 management issues;. 3. IS12000. 6500-D14/S14 Packet-Optical Platform. Choose the window size, which is the size of the virtual screen of the VNC viewer. 3802 XGS-PON Optical Network Unit. This architecture capacity. To add BGP peers, click Configure Peers at the top of the BGP Peers table, configure the settings shown in the following figure and table, and click Save. raciena6500. Port 4 and Port 9 are on the same virtual-switch and have the same VLAN. This command does not clear the boot variables, such as config-register and boot system settings. Configuring the Route Recorder. Waveserver Ai User Guide, Release 1. I need to know the CLI command to show the running configuration / provisioning data of a 6500 device. Guide for 6500 Alarm troubleshooting - Read online for free. 7) The 6500 Reconfigurable Line System (RLS) is a compact, simple-to-deploy, photonic layer solution that improves scalability, reduces footprint, and offers more flexibility and programmability. To enable multi-zone traffic at the top-level domain of the configuration hierarchy, select Add > Domain then select Multi Domain Traffic. Incorporates on-board RFC 2544 Performance Benchmark. You must configure the Route Recorder before configuring any other appliances in your deployment. I hope this helps. Choose MCP UI > System > Adaptive IP administration > Admin > Recorder Config in the web interface to open the Recorder Configuration page. Step 7: Compare the "Laser Centering" configured on both ends, they need to MATCH. racienaonid. UCM6204_quick_installation_guide. 0 255. Refer to the Optical Manager Element Adapter Technical Publication Library, Installation and Configuration Guide, 450-3121-201 for more information. Adaptive IP Guide. Node: A TAPI Node is an abstraction of a forwarding entity in the network. Proven reliability across the globe. Number of Views 6. 6. 3_Admin_Security)_Issue1. Step 6: Repeat steps "3" & "4". Click Edit. 6_CLI)_Issue1. The 6500-D2 is a 2RU chassis composed of two service card-carrying slots enabling customized configurations for the strictest connectivity requirements at the access Repacking the Switch. MCP: Policy management for updating license server on network elements. Basic Input/Output System. With the ability to provide on-demand connectivity and terabit switching, you can continually stay ahead of unpredictable customer demands with Ciena’s 6500 T-Series Packet Optical Platforms. The Performance Metrics or Performance Monitoring (PM) microservice orchestrates the collection of metrics from resources. Creates the lowest TCO at scale using Ciena’s Zero-Touch Provisioning. Stay Connected. 2 6500 RA logs can result in 6500 management issues; SAOS 8. Not for 6500 packet-optical shelves. Table 1. 6500-2 6500-D7 6500-S8 6500-D14 6500-S14 6500-S32 6500-T12 6500-T24 Figure 2. 6500 Network Element fails to get license from License Server. During case creation if the case being created is determined to be a minor case. pdf), Text File (. Please double check that it is the correct fuse. x/n), if you are not using DHCP addressing. 10; Hard disk space: Greater than 2 GB for a standalone installation; Processor: 2 GHz Intel Core i7 or equivalent. This acquisition doubled Ciena's size and increased its customer base to over 1000. " Wow a whole 1000 customers!The TOE will need to be booted and the procedures in [1] must be followed to complete the installation of Ciena 6500 software. This configuration allows the Photonic Control Plane in the network to select the optimal center frequency. The Cisco has a portchannel configuration in LACP which end's up in a Virtual Switch configuration in the Ciena 6500. About MCP Docs. Configuring an IS-IS Protocol Instance. IS-IS Recorder Settings. Only 50% of all other 6500 nodes are available. Ciena® cannot be responsible for unauthorized use of equipment and will not make allowance or credit for unauthorized use or access. The 6500 Reconfigurable Line System (RLS) is a compact, simple-to-deploy, photonic layer solution that improves scalability, reduces footprint, and offers more flexibility and programmability. Select Planning > Planning import/export. XDMCP (X Display Manager Control Protocol) opens a single port in this range. Command. Table 2. I have a 6500. 6500 Packet-Optical Platform) Step 4: Select the applicable software release version (ie. STEP 3: Confirm that all the involved fibers are correctly connected, review adjacency and the signal flow diagram. Schematics and illustrated parts list can also be included. Table 1. 6500-D14/S14 6500 Packet-Optical Platform. Additionally, the cost-effectiveness and versatility. REL12. mac show. pdf". 2) (ciena. This is a cheat list of the most used operational and troubleshooting Ciena Commands used in SAOS OS cli. All pluggable specification sheet is available in a separate document being published by Ciena Technical Publication document. The "Create configuration setting" dialog displays. After examining Adv Enet Config guide for SAOS, I. This is due to the case where a node such as a 6500 TIDc can have more than one L2 switch fabric (for example, one shelf is an AN and another is an AGN). Select BGP in the configuration hierarchy. Log into one of the host machines in the clustered solution with userID root. Steps. Ciena SAOS Collector Commands. MCP: Policy management for updating license server on network elements. The 6500 Reconfigurable Line System (RLS) is a compact, simple-to-deploy, photonic layer solution that improves scalability, reduces footprint, and offers more flexibility and programmability. In MCP a Node maps to a single physical device. 1. 2 Tb/s of unrestricted hybrid packet/OTN switching for an. Table 1. Use DHCP—Select to use DHCP addressing. Step 5:. BIP. 2. Ciena uses cookies to ensure that we give you the best experience when visiting our website, as well as to enhance the overall quality of our site. For the purposes of this. This feature is expected to work on 6500 Broadband, 6500 S Series PKTON. It provides highly dense. 757. Step 3: Now from site manager , go to configuration tab ---> Equipment and facility provisioning and. . rais12000. Procedure 1-1 Installing a 6500 14-slot shelf (all variants), access panel, cooling fan modules, and air plenum Use this procedure to install the 14-slot 6500 shelf into a 19-inch, 23-inch, or ETSI equipment rack. 5 (or later) customer documentation to add new ROADMs and perform system lineup and testing (SLAT) based on the. Table 3-3 Ciena products that interwork with 6130 Release 5. 0 and there you find 430 pages of planning guide in PDF format (NTRN10EG. Please note that TR547 v. 06. Note We recommend that you save the packaging material for use later if you need to move the chassis. Based on the Service-Aware Operating System (SAOS) used in all of Ciena’s Routing and Switching products it delivers a consistent set of benefits, including interoperability between. Steps. See “Configuring SNMP v3 Profiles” on page 3-48 for instructions on creating SNMP v3 profiles. Number of Views 79. Ciena’s 6500 Family of Packet-Optical Platforms enables you to stay ahead of unpredictable customer demands. Ciena’s 5171 Platform empowers advanced access networks with 100GbE packet services beyond the Central Offices and POP sites, enabling deployment into street cabinets and other uncontrolled locations. 6500 - planning guide. • Plug and play easy to install product – single command to install; auto configuration • Line interface – 2 x Wavelogic3 Modems with a 200Gbs port , 16QAM DWDM channels, C - band tunable, Capacity - 88 channel - 50GHz grid • Client interface – 10xQSFP+; 4x10GbE ( 10GBase- R) and 40GE ( 40GBase- R4) ; 4xQSFP28 Features and benefits. Kevin Mizerek (Ciena. The 6500 T-Series leverages the programmability of Ciena’s industry-leading WaveLogic™ Ai coherent technology, enabling operators to maximize fiber capacity and lower the cost of When the expected far-end address (FEA) is set on a 6500 CMD Tx adjacency facility, the Wave-Line Synchronizer application discovers the proper type of transmitter and autoprovisions basic configuration information, such as the transmitter type (for 6500), wavelength, nominal power, transmission mode (for WaveLogic Ai/WaveLogic 5e interfaces on. Continually stay ahead of unpredictable customer demands with Ciena’s proven 6500 D/S-Series Packet Optical Platforms. IS12000. 32500 THz/1566. Reduce your transport costs with double the capacity of 100G/200G solutions. click on the PDF icon to download the Web Site Manager for 6500 Windows. Multiple configuration options with fully modular 4-slot or 10-slot chassis variants. 43 and Transport Interface 4X10G OTR 4X XFP/4X SFP+ with Encryption, we need to know if these Ciena DWDM have compatibility to connect to SAN Cisco MDS 9706 Multilayer Director with. Features and benefits. 6500 T-Series. Step 2: Select Documentation. Figure 3. Step 2: Select Photonic Services from the drop down menu. racienaonid. MEF CE 2. This is the occurence identifier of the alarm on the device. pdf". I need to know the CLI command to show the running configuration / provisioning data of a 6500 device. Enter the name in the Name field exactly as it appears in the 'Key and Name' column in the preceding table. Installation Guide. It shows the mac table in your PC. @Note: Please make sure that third party network are transparent for GCC1 and GCC2. I checked in the Admin and installation guide but I did not find it. Take a database backup from the OME 6500. The 6500 S-Series shelf configurations are equipped with an agnostic, centralized packet/OTN switched fabric, scaling from 600Gb/s to 3. Generate commissioning scripts for a heterogeneous project (6500, Waveserver and Waveserver5). mac show. 1 provided basic NE management (a. Funcionality. 3 | P a g e 1 Introduction The Ciena 6500 S-Series and D-Series Packet Optical Platform, the Target of Evaluation (TOE), is a family of standalone hardware devices that run VxWorks and provide OSI Layer 0/1/2 network traffic management services. • Viewing the Configuration Hierarchy. We would like to show you a description here but the site won’t allow us. 8 Tb/s, with a minimal footprint and unprecedented operational simplicity. 1. Ciena’s 3928 Platform is a cost-effective platform for 10 Gb/s Ethernet service delivery in a variety of business or mobile backhaul environments. Built-In Test. Regards, Jojo. Yes, we have a test set connected to port 4 of the 3932 (RJ45). 8700 Packetwave Platform data sheet. Ciena 6500-D7/S8 Data Sheet Created Date: 2/14/2018 5:43:24 AM. What's the. set ciena-6500r-system:system id member [name <string>] Step 3: Logout and log back in to the shelf to confirm if the system name got updated. Supports 2 GbE NNI/UNI Small Form-factor Pluggable (SFP) ports. Ciena uses cookies to ensure that we give you the best experience when visiting our website, as well as to enhance the overall quality of our site.